DIGITAL DIGIFLOW CONTENT 6000 VOLUME Liters

SKU: DIGI6000R-L 
DIGITAL DIGIFLOW CONTENT 6000 VOLUME Liters
Price:
€32.64
You Save: 41% €55.49
FREE shipping€ 5,99
Free from € 15,00
starting from € 6.00 (see exceptions)
on Reservation Lowq Medium High 0

-or-  info
×
CUSTOMIZABLE ITEMS :
these are items that can be purchased individually as spare parts or by choosing the configuration wizard that completes them according to your needs.
Click on "Customize + Cart" button.
TEL. 0773 848566
WhatsApp
No video available for this product

Digital Counters
With Measurement: LITERS

CONNECTION: Input-Output: thread F / F 3/8 '' mnpt

For quick coupling to John Guest tubes
You need the purchase of No. 2 pieces (one in and one out) of the following fittings depending on the size of your pipe
(To check the size of the tube is printed on the tube itself):

3/8 -1/4 "Tube Adapter:> PI010823S
3/8 - 8mm Hose Adapter:> PM010813E
3/8 - 10mm Pipe Adapter:> PM011003E

 

When the set limit is reached depending on the capacity of the filter, the display will signal the blinking of the filter cartridge by audible alarm.
The meter is equipped with instantaneous flow rate detection.

It works on batteries (2 mins) of alkaline batteries with a life of up to one year.
When batteries run out, the latest processed data will automatically be stored in the instrument.

Batteries Installation
Slide the battery compartment cover and insert 2 batteries (AAA). Close the cover

Set filter capacity:
The counters can total 99,999 liters and monitor up to 5 different filters simultaneously.
Press and hold DISPLAY for 4-5 seconds. Then press RESET and release both buttons. The DigiFlow 6000R will enter the filter capacity registration process. The right digit will indicate a flashing "1" twice (indicates the filter number) and capacity.

Now press DISPLAY to select filter capacity n.1. The sequence is 100-200-300 ... .9800-19900-OFF-0-100 (Gallon-sized model) or 500-1000 ... .9500-OFF-500 (model in liters).
Holding DISPLAY can accelerate the selection sequence. After choosing the right capacity. Press RESET to save the setting. The procedure will go into filter configuration n.2. The second digit from the right will indicate a "2" blinking twice and the filter capacity n.1. Repeat the same procedure previously performed to configure up to 5 filters. The setup procedure will end. Returning to its original state. If there is no input for 10 seconds.

Operations
The DigiFlow 6000R will turn on automatically when there is any water passage through it. It will turn off automatically after 10 seconds if there is no water passage.

Press DISPLAY to display the current volume. Press DISPLAY again to display the remaining capacity of each filter. On the DigiFlow 6000R the filter number will flash 2 times and then indicate the remaining capacity for a total of 5 filters.

End Cap Alarm
When each filter reaches 0. the Digiflow will generate a sound alert to alert the user to change the cartridges. Press RESET to turn off the alarm and reset the filter capacity.

Low battery alarm
When the battery power is lower than the normal working level. A buzzer will emit two beeps to warn you to change the batteries. The information will be stored in memory if the battery is completely discharged or removed.

Reset
Press and hold RESET for 8 seconds to reset the counters.

Full descriptionClose description
×
Description

Digital Counters
With Measurement: LITERS

CONNECTION: Input-Output: thread F / F 3/8 '' mnpt

For quick coupling to John Guest tubes
You need the purchase of No. 2 pieces (one in and one out) of the following fittings depending on the size of your pipe
(To check the size of the tube is printed on the tube itself):

3/8 -1/4 "Tube Adapter:> PI010823S
3/8 - 8mm Hose Adapter:> PM010813E
3/8 - 10mm Pipe Adapter:> PM011003E

 

When the set limit is reached depending on the capacity of the filter, the display will signal the blinking of the filter cartridge by audible alarm.
The meter is equipped with instantaneous flow rate detection.

It works on batteries (2 mins) of alkaline batteries with a life of up to one year.
When batteries run out, the latest processed data will automatically be stored in the instrument.

Batteries Installation
Slide the battery compartment cover and insert 2 batteries (AAA). Close the cover

Set filter capacity:
The counters can total 99,999 liters and monitor up to 5 different filters simultaneously.
Press and hold DISPLAY for 4-5 seconds. Then press RESET and release both buttons. The DigiFlow 6000R will enter the filter capacity registration process. The right digit will indicate a flashing "1" twice (indicates the filter number) and capacity.

Now press DISPLAY to select filter capacity n.1. The sequence is 100-200-300 ... .9800-19900-OFF-0-100 (Gallon-sized model) or 500-1000 ... .9500-OFF-500 (model in liters).
Holding DISPLAY can accelerate the selection sequence. After choosing the right capacity. Press RESET to save the setting. The procedure will go into filter configuration n.2. The second digit from the right will indicate a "2" blinking twice and the filter capacity n.1. Repeat the same procedure previously performed to configure up to 5 filters. The setup procedure will end. Returning to its original state. If there is no input for 10 seconds.

Operations
The DigiFlow 6000R will turn on automatically when there is any water passage through it. It will turn off automatically after 10 seconds if there is no water passage.

Press DISPLAY to display the current volume. Press DISPLAY again to display the remaining capacity of each filter. On the DigiFlow 6000R the filter number will flash 2 times and then indicate the remaining capacity for a total of 5 filters.

End Cap Alarm
When each filter reaches 0. the Digiflow will generate a sound alert to alert the user to change the cartridges. Press RESET to turn off the alarm and reset the filter capacity.

Low battery alarm
When the battery power is lower than the normal working level. A buzzer will emit two beeps to warn you to change the batteries. The information will be stored in memory if the battery is completely discharged or removed.

Reset
Press and hold RESET for 8 seconds to reset the counters.

  • (1,665 KB)

Accessories

JOHN GUEST QUICK CONNECTION TERMINAL RIGHT (tube) 10mm X 3/8 (Thread)
Offer:
€6.48
You Save:
-41%
Listing
€11.02
JOHN QUICK CONNECTION GUEST TERMINAL RIGHT (tube) 8mm X 3/8 (thread) bsb
Offer:
€5.55
You Save:
-41%
Listing
€9.44
JOHN GUEST QUICK CONNECTION TERMINAL RIGHT (tube) 1/4 "X 3/8" (Thread)
Offer:
€4.53
You Save:
-41%
Listing
€7.70

Similar

DIGITAL DIGIFLOW 8000 TIME / VOLUME CONTENTS
Offer:
€33.11
You Save:
-41%
Listing
€56.29