TECHNICAL FEATURES:

Brand: Greenfilter
Production: 50 gdp

Actual surface: 0.37m² (4ft²) * Test pressure 4.5bar (65psi) * Production flow (N1) 9.45l / h (50gpd) * Salt rejection (N2) 97% * Recovery of 15%


OPERATION LIMITS 50, 75, 100 GPD
* Max. Temperature 45 ºC (113ºF)
* Max pressure 21bar (300 psi)
* Max. P for 1 bar (15 psi)
* Max Input Rate 7.6lpm (2.0 gpm)
* PH range, continuous operation 3-10
* PH range, term cleansing (30 min) 2-11
* Free chlorine tolerance¹ <0.1 ppm

OPERATION LIMITS 150, 180 GPD
* Max. Temperature 45 ºC (113ºF)
* Max. Pressure 8.6bar (125 psi)
* Max Input Rate 7.6lpm (2.0 gpm)
* PH range, continuous operation 3-10
* Free chlorine tolerance¹ <0.1 ppm

The membrane has some short-term resistance to chlorine (hypochlorite). Continuous exposure, however, can damage the membrane and should be avoided.

 

It is advisable to change the membranes of the reverse osmosis plant every 2/3 years max.

Replacement is simple and fast without the use of special tools.

Full descriptionClose description
×
Description

MEMBRANE RECOVERY GREENFILTER
FOR INVERSE OSMOSI SYSTEM
Mod. 1812 of 50 GPD


TECHNICAL FEATURES:

Brand: Greenfilter
Production: 50 gdp

Actual surface: 0.37m² (4ft²) * Test pressure 4.5bar (65psi) * Production flow (N1) 9.45l / h (50gpd) * Salt rejection (N2) 97% * Recovery of 15%


OPERATION LIMITS 50, 75, 100 GPD
* Max. Temperature 45 ºC (113ºF)
* Max pressure 21bar (300 psi)
* Max. P for 1 bar (15 psi)
* Max Input Rate 7.6lpm (2.0 gpm)
* PH range, continuous operation 3-10
* PH range, term cleansing (30 min) 2-11
* Free chlorine tolerance¹ <0.1 ppm

OPERATION LIMITS 150, 180 GPD
* Max. Temperature 45 ºC (113ºF)
* Max. Pressure 8.6bar (125 psi)
* Max Input Rate 7.6lpm (2.0 gpm)
* PH range, continuous operation 3-10
* Free chlorine tolerance¹ <0.1 ppm

The membrane has some short-term resistance to chlorine (hypochlorite). Continuous exposure, however, can damage the membrane and should be avoided.

 

It is advisable to change the membranes of the reverse osmosis plant every 2/3 years max.

Replacement is simple and fast without the use of special tools.

Accessories

Similar

FILMTEC TFC TW30 1812 - 100 GPD MEMBRANE MEMBRANE REPLACEMENT
Offer:
€44.41
You Save:
-41%
Listing
€75.49
REPLACEMENT MEMBRANE OSMOSIS GREENFILTER TFC 1812 - 100 GDP
Offer:
€24.25
You Save:
-41%
Listing
€41.24
REPLACEMENT MEMBRANE OSMOSIS GREENFILTER TFC 1812-75 GPD
Offer:
€21.96
You Save:
-41%
Listing
€37.33
REPLACEMENT MEMBRANE OSMOSIS GREENFILTER TFC 2012 - 180 GDP
Offer:
€45.30
You Save:
-41%
Listing
€77.01
REPLACEMENT MEMBRANE OSMOSIS GREENFILTER TFC 3012 - 300 GDP
Offer:
€69.67
You Save:
-41%
Listing
€118.44