REPLACEMENT MEMBRANE OSMOSIS GREENFILTER TFC 3012 - 300 GDP

SKU: 090005-300
REPLACEMENT MEMBRANE OSMOSIS GREENFILTER TFC 3012 - 300 GDP
  • REPLACEMENT MEMBRANE OSMOSIS GREENFILTER TFC 3012 - 300 GDP
  • REPLACEMENT MEMBRANE OSMOSIS GREENFILTER TFC 3012 - 300 GDP
Price:
€69.67
You Save: 41% €118.44
FREE shipping€ 4,99
Free from € 36,00
starting from € 6.00 (see exceptions)
on Reservation Lowq Medium High 8

TEL. 0773 848566
WhatsApp
No video available for this product

MEMBRANE RECOVERY GREENFILTER
FOR INVERSE OSMOSI SYSTEM
Mod. 3012 of 300 GPD


TECHNICAL FEATURES:

Brand: Greenfilter
Production: 300 gdp

Active area: x, xxm² (xft²) * Test pressure x, xbar (xxpsi) * production flow (N1) xx, xx l / h (300gpd) * rejection Sali (N2) 95% * 15% Recovery


OPERATION LIMITS 50, 75, 100 GPD
* Max. Temperature 45 ºC (113ºF)
* Max pressure 21bar (300 psi)
* Max. P for 1 bar (15 psi)
* Max Input Rate 7.6lpm (2.0 gpm)
* PH range, continuous operation 3-10
* PH range, term cleansing (30 min) 2-11
* Free chlorine tolerance¹ <0.1 ppm

OPERATION LIMITS 150, 180 GPD
* Max. Temperature 45 ºC (113ºF)
* Max. Pressure 8.6bar (125 psi)
* Max Input Rate 7.6lpm (2.0 gpm)
* PH range, continuous operation 3-10
* Free chlorine tolerance¹ <0.1 ppm

The membrane has some short-term resistance to chlorine (hypochlorite). Continuous exposure, however, can damage the membrane and should be avoided.

 

It is advisable to change the membranes of the reverse osmosis plant every 2/3 years max.

Replacement is simple and fast without the use of special tools.

Full descriptionClose description
×
Description

MEMBRANE RECOVERY GREENFILTER
FOR INVERSE OSMOSI SYSTEM
Mod. 3012 of 300 GPD


TECHNICAL FEATURES:

Brand: Greenfilter
Production: 300 gdp

Active area: x, xxm² (xft²) * Test pressure x, xbar (xxpsi) * production flow (N1) xx, xx l / h (300gpd) * rejection Sali (N2) 95% * 15% Recovery


OPERATION LIMITS 50, 75, 100 GPD
* Max. Temperature 45 ºC (113ºF)
* Max pressure 21bar (300 psi)
* Max. P for 1 bar (15 psi)
* Max Input Rate 7.6lpm (2.0 gpm)
* PH range, continuous operation 3-10
* PH range, term cleansing (30 min) 2-11
* Free chlorine tolerance¹ <0.1 ppm

OPERATION LIMITS 150, 180 GPD
* Max. Temperature 45 ºC (113ºF)
* Max. Pressure 8.6bar (125 psi)
* Max Input Rate 7.6lpm (2.0 gpm)
* PH range, continuous operation 3-10
* Free chlorine tolerance¹ <0.1 ppm

The membrane has some short-term resistance to chlorine (hypochlorite). Continuous exposure, however, can damage the membrane and should be avoided.

 

It is advisable to change the membranes of the reverse osmosis plant every 2/3 years max.

Replacement is simple and fast without the use of special tools.

Accessories

Similar

FILMTEC TFC TW30 1812 - 100 GPD MEMBRANE MEMBRANE REPLACEMENT
Offer:
€44.38
You Save:
-41%
Listing
€75.45
REPLACEMENT MEMBRANE OSMOSIS GREENFILTER TFC 1812-50 GPD
Offer:
€20.96
You Save:
-41%
Listing
€35.62
REPLACEMENT MEMBRANE OSMOSIS GREENFILTER TFC 1812 - 100 GDP
Offer:
€24.25
You Save:
-41%
Listing
€41.24
REPLACEMENT MEMBRANE OSMOSIS GREENFILTER TFC 1812-75 GPD
Offer:
€21.96
You Save:
-41%
Listing
€37.33
REPLACEMENT MEMBRANE OSMOSIS GREENFILTER TFC 2012 - 180 GDP
Offer:
€45.30
You Save:
-41%
Listing
€77.01