Steril-Soft ForHome® Chlorine Manufacturer For Softeners with Titanium Electrode, o-ring, and Starfit 3/8 "fittings

 

Automatic disinfection system for water softeners from 0 to 90 lt. resin.

 

Important:

the set time must be less than the duration of the brine suction cycle, so as to avoid overheating and damage to the electrode compartment.

 

Adjustment instruction:

* By adjusting the TIME potentiometer inside the system, Steril-Soft can be adapted to softeners with capacity up to 90 L of resin.

* The AMPERE potentiometer (current intensity from 0.2 to 2.5 A) allows instead to adjust the amount of chlorine produced. The greater the amount of resin (and therefore the

injector flow rate), the greater the amount of chlorine to be produced to ensure sufficient concentration on the resin.

* The TIME potentiometer allows you to adjust the chlorine production time from 2 to 20 minutes. Once the production cycle has ended, the device remains off for 20 minutes before starting a new cycle.

Full descriptionClose description
×
Description

Steril-Soft ForHome® Chlorine Manufacturer For Softeners with Titanium Electrode, o-ring, and Starfit 3/8 "fittings

 

Automatic disinfection system for water softeners from 0 to 90 lt. resin.

 

Important:

the set time must be less than the duration of the brine suction cycle, so as to avoid overheating and damage to the electrode compartment.

 

Adjustment instruction:

* By adjusting the TIME potentiometer inside the system, Steril-Soft can be adapted to softeners with capacity up to 90 L of resin.

* The AMPERE potentiometer (current intensity from 0.2 to 2.5 A) allows instead to adjust the amount of chlorine produced. The greater the amount of resin (and therefore the

injector flow rate), the greater the amount of chlorine to be produced to ensure sufficient concentration on the resin.

* The TIME potentiometer allows you to adjust the chlorine production time from 2 to 20 minutes. Once the production cycle has ended, the device remains off for 20 minutes before starting a new cycle.