WS1CI Clack softener valve 1 "- Volume, Time with injector C, without DLFC, mixing - down flow (or)

SKU: 15010301-001
WS1CI Clack softener valve 1 "- Volume, Time with injector C, without DLFC, mixing - down flow (or)
Price:
€368.38
You Save: 41% €626.25
FREE shipping€ 4,99
Free from € 15,00
starting from € 6.00 (see exceptions)
on Reservation Lowq Medium High 0

-or-  info
×
CONFIGURABLE ITEMS :
these are items that can be purchased individually as spare parts or by choosing the configuration wizard that completes them according to your needs.
Click on "Complete and configure" button.
TEL. 0773 848566
WhatsApp
No video available for this product

WS1CI Clack softener valve 1 "- Volume, Time with injector C, without DLFC, mixing - down flow (or)

 

Water Specialist with 1 "CI Control Valve

Shown with bypass option

* Solid state microprocessor, with easy access to the front control panel.

* Three methods of operation; immediate volumetric, delayed volumetric, time delayed

* Programmable in ppm, French degrees, German degrees, or cubic meters

* Fully programmable regeneration cycle sequence (maximum 9)

* Programmable regeneration cycle times

* Daily overwrite function; 1 - 28 days available

* Backwash and brine capacity for cylinders up to 22 "in diameter

* Downflow / upflow regeneration

* Storage of system configurations and operating data in non-volatile memory

* Back-up capacitor with power up to 2 hours

* Output with 12 volt AC power supply provides safe and easy installation

* Valve design allows for optimized backwash and service

* Regenerating filling with treated water

* Available with Mixing valve option

* Low salt alarm

* 24 hour clock

* Reliable and tested DC Drive

 

Specifications

Inlet / outlet fittings: 1 "

Cycles: up to 9

Valves material: Noryl (1) or equivalent

Regeneration: downflow / upflow

 

flow

Service @ 15 psi / 1 bar pressure drop (includes bypass and counter): 102 lpm

Backwash @ 25 psi / 1.7 bar pressure drop (includes bypass): 102 lpm

 

Operating pressure

Minimum / Maximum: 20 - 125 psi (1.4 - 8.6 bar)

 

Operating temperature

Minimum / Maximum: 40º - 110º F (4º - 43º C)

 

Counter

Accuracy: ± 5%

Flow range: 1 - 102 lpm

Volume range: 0.10 m3 - 2000.0 m3

Totalizer: 1 m3 - 99.999 m3

 

Dimensions and weight

Pilot distributor: 1.050 "OD Pipe (¾" NPS)

Drain line: 3/4 "or 1" NPT

Brine line: 3/8 "or 1/2" OD Poly tube

Mounting base: 2-1 / 2 "- 8 NPSM

Height from the top of the cylinder: 7 3/8 "(187 mm)

Weight: 4.5 lbs (2 kg)

 

Electrical specifications AC adapter

Supply voltage: 230V AC

Supply frequency: 50 Hz

Output voltage: 12V AC

Output current: 500 mA

 

Cylinder Applications

Softener: Diameter 6 "- 22"

Filter (2): Diameter 6 "- 22"

 

Operation cycles

Choose up to nine regeneration cycles, in any order,

with a wide range of values ​​available:

Backwash: 1 - 120 minutes

Rinse: 1 - 120 minutes

Break (service): 1 - 480 minutes

Brine (co-current): 1 - 180 minutes

Brine (countercurrent): 1 - 180 minutes

Filling (softener): 0.05 - 95.00 kg

Filling (filter): 0.05 - 95.00 lt

 

Options: Backwash filter, bypass, weather protection

Compatible with the following typical concentrations of regenerants or chemicals: sodium chloride, potassium chloride, potassium permanganate, sodium bisulfite, chlorine and chloramines.

Full descriptionClose description
×
Description

WS1CI Clack softener valve 1 "- Volume, Time with injector C, without DLFC, mixing - down flow (or)

 

Water Specialist with 1 "CI Control Valve

Shown with bypass option

* Solid state microprocessor, with easy access to the front control panel.

* Three methods of operation; immediate volumetric, delayed volumetric, time delayed

* Programmable in ppm, French degrees, German degrees, or cubic meters

* Fully programmable regeneration cycle sequence (maximum 9)

* Programmable regeneration cycle times

* Daily overwrite function; 1 - 28 days available

* Backwash and brine capacity for cylinders up to 22 "in diameter

* Downflow / upflow regeneration

* Storage of system configurations and operating data in non-volatile memory

* Back-up capacitor with power up to 2 hours

* Output with 12 volt AC power supply provides safe and easy installation

* Valve design allows for optimized backwash and service

* Regenerating filling with treated water

* Available with Mixing valve option

* Low salt alarm

* 24 hour clock

* Reliable and tested DC Drive

 

Specifications

Inlet / outlet fittings: 1 "

Cycles: up to 9

Valves material: Noryl (1) or equivalent

Regeneration: downflow / upflow

 

flow

Service @ 15 psi / 1 bar pressure drop (includes bypass and counter): 102 lpm

Backwash @ 25 psi / 1.7 bar pressure drop (includes bypass): 102 lpm

 

Operating pressure

Minimum / Maximum: 20 - 125 psi (1.4 - 8.6 bar)

 

Operating temperature

Minimum / Maximum: 40º - 110º F (4º - 43º C)

 

Counter

Accuracy: ± 5%

Flow range: 1 - 102 lpm

Volume range: 0.10 m3 - 2000.0 m3

Totalizer: 1 m3 - 99.999 m3

 

Dimensions and weight

Pilot distributor: 1.050 "OD Pipe (¾" NPS)

Drain line: 3/4 "or 1" NPT

Brine line: 3/8 "or 1/2" OD Poly tube

Mounting base: 2-1 / 2 "- 8 NPSM

Height from the top of the cylinder: 7 3/8 "(187 mm)

Weight: 4.5 lbs (2 kg)

 

Electrical specifications AC adapter

Supply voltage: 230V AC

Supply frequency: 50 Hz

Output voltage: 12V AC

Output current: 500 mA

 

Cylinder Applications

Softener: Diameter 6 "- 22"

Filter (2): Diameter 6 "- 22"

 

Operation cycles

Choose up to nine regeneration cycles, in any order,

with a wide range of values ​​available:

Backwash: 1 - 120 minutes

Rinse: 1 - 120 minutes

Break (service): 1 - 480 minutes

Brine (co-current): 1 - 180 minutes

Brine (countercurrent): 1 - 180 minutes

Filling (softener): 0.05 - 95.00 kg

Filling (filter): 0.05 - 95.00 lt

 

Options: Backwash filter, bypass, weather protection

Compatible with the following typical concentrations of regenerants or chemicals: sodium chloride, potassium chloride, potassium permanganate, sodium bisulfite, chlorine and chloramines.